# FDA Product Code DSQ: Ventricular (Assist) Bypass

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/DSQ
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=DSQ
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/DSQ/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=DSQ

## FDA CDRH Classification Metadata
- **Product Code**: `DSQ`
- **Device Name**: Ventricular (Assist) Bypass
- **Device Class**: Class 3
- **21 CFR Regulation Number**: `N/A`
- **Medical Specialty / Review Panel**: CV (CV)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: Approved pma:  P870072

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 9 / 712
- **FDA AccessGUDID Published Devices**: 358
- **FDA MAUDE Adverse Event Reports**: 159,529 (Deaths: 23,330, Injuries: 76,812, Malfunctions: 59,240)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 1 | 11 | 20,215 | 2,109 |
| 2020 | 0 | 0 | 20 | 14,239 | 1,764 |
| 2021 | 0 | 0 | 2 | 15,765 | 2,325 |
| 2022 | 0 | 0 | 17 | 15,994 | 2,260 |
| 2023 | 0 | 0 | 1 | 13,055 | 3,503 |
| 2024 | 0 | 0 | 1 | 13,046 | 2,083 |
| 2025 | 0 | 0 | 26 | 10,581 | 2,122 |
| 2026 | 0 | 0 | 13 | 7,685 | 1,265 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| No 510(k) applicants recorded | 0 | — |

## Recent FDA 510(k) Clearances
- No recent 510(k) clearances recorded for this product code.

## Recent FDA PMA Approvals & Supplements
- **`P170038`**/S036 (2026-11-13) — **Abbott**: CentriMag™ Circulatory Support System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P170038S036))
- **`P170038`**/S034 (2026-10-30) — **Abbott**: CentriMag™ Circulatory Support System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P170038S034))
- **`P160035`**/S054 (2026-10-30) — **Berlin Heart, Inc.**: EXCOR Pediatric Ventricular Assist Device ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160035S054))
- **`P160035`**/S061 (2026-10-28) — **Berlin Heart, Inc.**: EXCOR Pediatric VAD ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160035S061))
- **`P160035`**/S060 (2026-10-23) — **Berlin Heart, Inc.**: EXCOR Pediatric Ventricular Assist Device ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160035S060))
- **`P160054`**/S136 (2026-10-19) — **ABBOTT MEDICAL**: HeartMate 3 Left Ventricular Assist System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160054S136))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "DSQ"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*