# FDA Product Code GBW: Catheter, Peritoneal

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/GBW
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=GBW
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/GBW/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=GBW

## FDA CDRH Classification Metadata
- **Product Code**: `GBW`
- **Device Name**: Catheter, Peritoneal
- **Device Class**: Class 1
- **21 CFR Regulation Number**: `878.4200`
- **Medical Specialty / Review Panel**: SU (SU)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: Official FDA CDRH device classification category.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 17
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 126
- **FDA MAUDE Adverse Event Reports**: 135 (Deaths: 6, Injuries: 65, Malfunctions: 57)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2018 | 0 | 0 | 16 | 10 | 0 |
| 2019 | 0 | 0 | 5 | 1 | 0 |
| 2020 | 0 | 0 | 5 | 3 | 0 |
| 2021 | 0 | 0 | 15 | 8 | 5 |
| 2022 | 0 | 0 | 2 | 6 | 0 |
| 2023 | 0 | 0 | 3 | 28 | 1 |
| 2024 | 0 | 0 | 4 | 0 | 0 |
| 2026 | 0 | 0 | 28 | 17 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Sil-Med Corp. | 4 | 1996-08-08 |
| Taut, Inc. | 3 | 1999-10-05 |
| Sherwood Medical Co. | 1 | 1994-02-24 |
| Research Medical, Inc. | 1 | 1986-02-11 |
| Vascular Products, Inc. | 1 | 1991-10-08 |
| Arrow Intl., Inc. | 1 | 1981-08-10 |
| Medical Components, Inc. | 1 | 1996-03-21 |
| A.D.T. Lab Industries | 1 | 1980-03-12 |
| Madegom | 1 | 1989-08-18 |
| Medi-Tech, Inc. | 1 | 1981-06-02 |

## Recent FDA 510(k) Clearances
- **`K992907`** (1999-10-05) — **Taut, Inc.**: INTRADUCER ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K992907))
- **`K992904`** (1999-10-05) — **Taut, Inc.**: MINI-PORT ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K992904))
- **`K972112`** (1997-12-01) — **Taut, Inc.**: INTRADUCER PORT SC CATALOG#31275,31035,30915, AND 31450 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K972112))
- **`K961194`** (1996-08-08) — **Sil-Med Corp.**: ANTIMICROBIAL MEDIASTINAL SILICONE DRAIN ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K961194))
- **`K960426`** (1996-03-21) — **Medical Components, Inc.**: MEDICOMP FLEXI-SMOOTH WOUND DRAINAGE CATHETER ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K960426))
- **`K942709`** (1996-01-04) — **Sil-Med Corp.**: MEDIASTINAL SILICONE DRAINS ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K942709))
- **`K933510`** (1994-02-24) — **Sherwood Medical Co.**: ARGYLE TURKEL SAFETY TROCAR THORACIC CATHETER ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K933510))
- **`K926477`** (1993-11-12) — **Core Dynamics, Inc.**: BIFURCATED SUCTION/IRRIGAT TUBING SET W/PUSH BUTTO ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K926477))
- **`K913733`** (1991-10-08) — **Vascular Products, Inc.**: STERILE CHEST TUBE ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K913733))
- **`K894220`** (1989-08-24) — **Helix Medical, Inc.**: HOUTS HYSTERECTOMY DRAIN ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K894220))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "GBW"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*