# FDA Product Code IKT: Electrode, Needle, Diagnostic Electromyograph

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/IKT
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=IKT
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/IKT/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=IKT

## FDA CDRH Classification Metadata
- **Product Code**: `IKT`
- **Device Name**: Electrode, Needle, Diagnostic Electromyograph
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `890.1385`
- **Medical Specialty / Review Panel**: PM (NE)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: True
- **Definition**: Official FDA CDRH device classification category.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 43
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 943
- **FDA MAUDE Adverse Event Reports**: 149 (Deaths: 0, Injuries: 52, Malfunctions: 85)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 37 | 15 | 0 |
| 2020 | 0 | 0 | 3 | 3 | 0 |
| 2021 | 0 | 0 | 49 | 5 | 0 |
| 2022 | 0 | 0 | 26 | 4 | 0 |
| 2023 | 0 | 0 | 102 | 8 | 0 |
| 2024 | 0 | 0 | 89 | 9 | 0 |
| 2025 | 0 | 0 | 35 | 3 | 0 |
| 2026 | 1 | 0 | 37 | 0 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Chalgren Enterprises, Inc. | 9 | 1999-06-22 |
| Medicotest A/S | 3 | 2002-06-14 |
| Rhythmlink International, LLC | 3 | 2012-06-22 |
| Dantec Medical, Inc. | 3 | 1994-10-04 |
| Natus Manufacturing Limited | 3 | 2018-06-29 |
| Technomed Europe | 3 | 2026-03-15 |
| Medtronic Functional Diagnostics A/S | 2 | 2001-08-15 |
| Nihon Kohden America, Inc. | 2 | 1987-03-13 |
| Carefusion 209, Inc. | 2 | 2011-08-12 |
| Medelec, Inc. D.B.A. Teca Corp. | 2 | 1997-11-20 |

## Recent FDA 510(k) Clearances
- **`K253581`** (2026-03-15) — **Technomed Europe**: Disposable Concentric Needle Electrode 0.30x25mm Red (TE/B50700-001); Disposable Concentric Needle Electrode 0.40x25mm Yellow (TE/B50700-002); Disposable Concentric Needle Electrode 0.30x30mm Pink (TE/B50700-006); Disposable Concentric Needle Electrode 0.45x37mm Green (TE/B50700-003); Disposable Concentric Needle Electrode 0.45x50mm Blue (TE/B50700-004); Disposable Concentric Needle Electrode 0.60x75mm Violet (TE/B50700-005) ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K253581))
- **`K173815`** (2018-06-29) — **Natus Manufacturing Limited**: Allergan Botox Needle Electrode ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K173815))
- **`K161430`** (2017-03-02) — **Natus Manufacturing Limited**: Myoject Luer Lock Needle Electrode ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K161430))
- **`K152984`** (2016-06-03) — **Bio Protech, Inc.**: Disposable Concentric Needle electrodes, Disposable Monopolar Needle electrodes, Disposable EP Needle electrodes, Disposable Hypodermic Needle electrodes ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K152984))
- **`K143433`** (2015-08-28) — **Natus Manufacturing Limited**: Dantec DCN Disposable Concentric Needle Electrodes-25mm, Dantec DCN Disposable Concentric Needle Electrodes-37mm, Dantec DCN Disposable Concentric Needle Electrodes-50mm, Dantec DCN Disposable Concentric Needle Electrodes-75mm ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K143433))
- **`K120342`** (2012-06-22) — **Rhythmlink International, LLC**: EMG RECORDING ELECTRODE ASSEMBLY ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K120342))
- **`K112034`** (2011-08-12) — **Carefusion 209, Inc.**: TECA ELITE DISPOSABLE CONCENTRIC NEEDLES ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K112034))
- **`K111131`** (2011-06-17) — **Carefusion 209, Inc.**: TECA (TM) ELITE DISPOSABLE MONOPOLAR NEEDLES ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K111131))
- **`K092973`** (2010-10-07) — **Bionen S.A.S.**: DISPOSABLE AND REUSABLE CONCENTRIC NEEDLES / DISPOSABLE AND REUSABLE MONOPOLAR NEEDLE ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K092973))
- **`K093825`** (2010-01-13) — **Ambu A/S**: AMBU NEUROLINE DISPOSABLE INOJECT NEEDLE ELECTRODE ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K093825))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "IKT"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*