# FDA Product Code JMG: Radioimmunoassay (Two-Site Solid Phase), Ferritin

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/JMG
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=JMG
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/JMG/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=JMG

## FDA CDRH Classification Metadata
- **Product Code**: `JMG`
- **Device Name**: Radioimmunoassay (Two-Site Solid Phase), Ferritin
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `866.5340`
- **Medical Specialty / Review Panel**: IM (CH)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: True
- **Definition**: Official FDA CDRH device classification category.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 24
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 23
- **FDA MAUDE Adverse Event Reports**: 86 (Deaths: 1, Injuries: 1, Malfunctions: 84)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 4 | 1 | 0 |
| 2020 | 0 | 0 | 5 | 4 | 0 |
| 2021 | 0 | 0 | 0 | 5 | 0 |
| 2022 | 0 | 0 | 0 | 2 | 0 |
| 2023 | 0 | 0 | 0 | 13 | 0 |
| 2024 | 1 | 0 | 1 | 11 | 0 |
| 2025 | 0 | 0 | 0 | 13 | 0 |
| 2026 | 0 | 0 | 1 | 13 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Beckman Coulter, Inc. | 2 | 2024-03-20 |
| Bd Becton Dickinson Vacutainer Systems Preanalytic | 2 | 1980-01-11 |
| Corning Medical & Scientific | 2 | 1984-03-30 |
| Diagnostic Products Corp. | 2 | 1993-01-13 |
| Boehringer Mannheim Corp. | 2 | 1997-07-30 |
| New England Nuclear | 1 | 1979-01-10 |
| Cambridge Medical Technology | 1 | 1989-03-16 |
| Microgenics Corp. | 1 | 1992-06-04 |
| Dade Chemistry Systems, Inc. | 1 | 1997-01-24 |
| Ria Products, Inc. | 1 | 1979-01-10 |

## Recent FDA 510(k) Clearances
- **`K234052`** (2024-03-20) — **Beckman Coulter, Inc.**: Access Ferritin ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K234052))
- **`K052082`** (2005-08-19) — **Beckman Coulter, Inc.**: FERRITIN ON THE ACCESS IMMUNOASSAY SYSTEMS, MODEL 33020 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K052082))
- **`K964282`** (1997-07-30) — **Boehringer Mannheim Corp.**: TINA-QUANT FERRITIN ASSAY ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K964282))
- **`K971833`** (1997-06-02) — **Boehringer Mannheim Corp.**: ELECSYS FERRITIN ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K971833))
- **`K963498`** (1997-01-24) — **Dade Chemistry Systems, Inc.**: FERR FLEX REAGENT CARTRIDGE ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K963498))
- **`K950393`** (1995-05-16) — **Schiapparelli Biosystems, Inc.**: ACE(TM) CEDIA(R) FERRITIN ASSAY ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K950393))
- **`K925848`** (1993-01-13) — **Diagnostic Products Corp.**: IMMULITE FERRITIN ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K925848))
- **`K926221`** (1993-01-13) — **Bio-Rad Laboratories, Inc.**: ACCESS FERRITIN ASSAY ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K926221))
- **`K920829`** (1992-06-19) — **Roche Diagnostic Systems, Inc.**: COBAS CORE FERRITIN EIA ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K920829))
- **`K920318`** (1992-06-04) — **Microgenics Corp.**: CEDIA FERRITIN ASSAY ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K920318))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "JMG"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*
