# FDA Product Code JOQ: Generator, Pulse, Pacemaker, External Programmable (For Electrophysiological Studies Only)

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/JOQ
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=JOQ
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/JOQ/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=JOQ

## FDA CDRH Classification Metadata
- **Product Code**: `JOQ`
- **Device Name**: Generator, Pulse, Pacemaker, External Programmable (For Electrophysiological Studies Only)
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `870.1750`
- **Medical Specialty / Review Panel**: CV (CV)
- **Implantable**: False | **Life-Sustaining**: True | **Third-Party Eligible**: False
- **Definition**: Official FDA CDRH device classification category.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 18
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 1 / 5
- **FDA AccessGUDID Published Devices**: 26
- **FDA MAUDE Adverse Event Reports**: 147 (Deaths: 2, Injuries: 46, Malfunctions: 72)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 3 | 4 | 0 |
| 2020 | 0 | 0 | 0 | 2 | 0 |
| 2021 | 0 | 0 | 1 | 2 | 0 |
| 2022 | 0 | 0 | 0 | 4 | 0 |
| 2023 | 0 | 0 | 0 | 10 | 0 |
| 2024 | 0 | 0 | 0 | 8 | 0 |
| 2025 | 0 | 0 | 7 | 5 | 0 |
| 2026 | 0 | 0 | 2 | 2 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Medtronic Vascular | 4 | 1986-08-04 |
| Ep Medsystems | 3 | 2009-10-16 |
| Micropace Pty, Ltd. | 2 | 2007-10-26 |
| Cordis Corp. | 1 | 1985-06-11 |
| Radionics, Inc. | 1 | 1996-11-08 |
| Seamed Corp. | 1 | 1985-09-12 |
| Fischer Medical Technologies, Inc. | 1 | 2000-05-05 |
| Heartware Intl. Corp. | 1 | 1989-10-02 |
| Fischer Medical | 1 | 2018-03-29 |
| St Cardio Technologies, LLC | 1 | 2007-07-02 |

## Recent FDA 510(k) Clearances
- **`K173439`** (2018-03-29) — **Fischer Medical**: Bloom2 Programmable Electrophysiology Stimulator ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K173439))
- **`K092913`** (2009-10-16) — **Ep Medsystems**: EP-4TM CARDIAC STIMULATOR, MODELS: EP-04-02, EP-04-04 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K092913))
- **`K072200`** (2007-10-26) — **Micropace Pty, Ltd.**: STIMLAB ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K072200))
- **`K070743`** (2007-07-02) — **St Cardio Technologies, LLC**: Z6 STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K070743))
- **`K041442`** (2004-09-14) — **Ep Medsystems**: EP-4 CLINICAL STIMUTATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K041442))
- **`K040207`** (2004-02-27) — **Ep Medsystems**: EP-4 CLINICAL STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K040207))
- **`K011826`** (2002-01-24) — **Micropace Pty, Ltd.**: EPS320 CARDIAC STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K011826))
- **`K991293`** (2000-05-05) — **Fischer Medical Technologies, Inc.**: EPSTIM ELECTROPHYSIOLOGY STIMULATOR CONTROL PROGRAM, BLOOM DTU-215 ELECTROPHYSIOLOGY PROGRAMMABLE STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K991293))
- **`K963579`** (1996-11-08) — **Radionics, Inc.**: PACE-1A CARDIAC STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K963579))
- **`K935590`** (1994-05-05) — **Ep Medical, Inc.**: EP MEDICAL, INC. EP-3 CLINICAL STIMULATOR ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K935590))

## Recent FDA PMA Approvals & Supplements
- **`P920032`**/S005 (2000-02-02) — **Pace Medical**: MICRO-PACE DUAL-CHAMBER, DDD, TEMPORARY CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032S005))
- **`P920032`**/S004 (1998-02-27) — **Pace Medical**: MODEL 4553 DUAL CHAM. DDD TEMP.CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032S004))
- **`P920032`**/S003 (1996-07-19) — **Pace Medical**: MODEL 4553 DUAL CHAM. DDD TEMP.CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032S003))
- **`P920032`**/S002 (1996-04-26) — **Pace Medical**: MICRO-PACE MODEL 4553 DUAL CHAMBER DDD TEMPORARY CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032S002))
- **`P920032`**/S001 (1995-08-28) — **Pace Medical**: MODEL 4553 DUAL CHAM. DDD TEMP.CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032S001))
- **`P920032`** (1994-03-10) — **Pace Medical**: MODEL 4553 DUAL CHAM. DDD TEMP.CARDIAC PACEMAKER ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P920032))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "JOQ"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*