# FDA Product Code KYF: Implant, Eye Valve

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/KYF
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=KYF
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/KYF/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=KYF

## FDA CDRH Classification Metadata
- **Product Code**: `KYF`
- **Device Name**: Implant, Eye Valve
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `886.3920`
- **Medical Specialty / Review Panel**: OP (OP)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: Official FDA CDRH device classification category.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 25
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 31
- **FDA MAUDE Adverse Event Reports**: 4,454 (Deaths: 0, Injuries: 3,099, Malfunctions: 1,345)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 1 | 0 | 2 | 516 | 0 |
| 2020 | 0 | 0 | 1 | 437 | 0 |
| 2021 | 0 | 0 | 0 | 412 | 0 |
| 2022 | 1 | 0 | 2 | 299 | 0 |
| 2023 | 2 | 0 | 0 | 314 | 0 |
| 2024 | 0 | 0 | 2 | 364 | 0 |
| 2025 | 0 | 0 | 1 | 281 | 0 |
| 2026 | 0 | 0 | 1 | 220 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| New World Medical, Inc. | 9 | 2023-05-12 |
| Iop, Inc. | 3 | 2006-09-27 |
| Hood Laboratories | 2 | 1991-03-15 |
| Optonol, Ltd. | 2 | 2003-03-13 |
| Optimed, Inc. | 1 | 1990-10-16 |
| Glaukos Corporation | 1 | 2022-08-02 |
| Precision-Cosmet Co., Inc. | 1 | 1985-02-15 |
| Innovative Ophthalmic Products, Inc. (Iop) | 1 | 2015-12-17 |
| Pharmacia Iovision, Inc. | 1 | 1997-02-18 |
| Allergan, Inc. | 1 | 2016-11-21 |

## Recent FDA 510(k) Clearances
- **`K230975`** (2023-05-12) — **New World Medical, Inc.**: Ahmed® Glaucoma Valve Model FP7 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K230975))
- **`K231051`** (2023-05-12) — **New World Medical, Inc.**: Ahmed® Glaucoma Valve Model FP8 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K231051))
- **`K220032`** (2022-08-02) — **Glaukos Corporation**: iStent infinite Trabecular Micro-Bypass System, Model iS3 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K220032))
- **`K182518`** (2019-01-18) — **New World Medical, Inc.**: AHMED ClearPath Glaucoma Drainage Device ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K182518))
- **`K171451`** (2017-08-08) — **New World Medical, Inc.**: Ahmed Glaucoma Valve Model FP8 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K171451))
- **`K161457`** (2016-11-21) — **Allergan, Inc.**: XEN Glaucoma Treatment System ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K161457))
- **`K162060`** (2016-10-24) — **New World Medical, Inc.**: Ahmed Glaucoma Valve ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K162060))
- **`K152996`** (2015-12-17) — **Innovative Ophthalmic Products, Inc. (Iop)**: Molteno3 Glaucoma Implant ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K152996))
- **`K062252`** (2006-09-27) — **Iop, Inc.**: MOLTENO3 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K062252))
- **`K060644`** (2006-09-18) — **New World Medical, Inc.**: AHMED GLAUCOMA VALVE, MODEL M4 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K060644))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "KYF"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*