# FDA Product Code MDI: Prosthesis, Rib Replacement

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/MDI
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=MDI
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/MDI/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=MDI

## FDA CDRH Classification Metadata
- **Product Code**: `MDI`
- **Device Name**: Prosthesis, Rib Replacement
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `888.3070`
- **Medical Specialty / Review Panel**: OR (OR)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: In children with or at risk of developing Thoracic Insufficiency Syndrome, the expandable rib prosthesis devices mechanically stabilize and/or correct thoracic deformities to allow the chest and lungs to grow. The devices are attached perpendicularly to the subject's natural ribs and lumbar vertebra or pelvis. This mechanically stabilizes the chest wall and enlarges the thorax to improve respiration and lung growth. The devices allow assembly in a number of different configurations to accommodate the wide variety of anatomical deformities encountered by the clinician in treating patients with or at risk of developing Thoracic Insufficiency Syndrome.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 2
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 211
- **FDA MAUDE Adverse Event Reports**: 1,051 (Deaths: 15, Injuries: 907, Malfunctions: 126)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 0 | 136 | 0 |
| 2020 | 0 | 0 | 0 | 4 | 0 |
| 2021 | 0 | 0 | 0 | 94 | 0 |
| 2022 | 0 | 0 | 0 | 27 | 1 |
| 2023 | 0 | 0 | 1 | 4 | 0 |
| 2024 | 1 | 0 | 37 | 20 | 0 |
| 2025 | 0 | 0 | 0 | 1 | 0 |
| 2026 | 0 | 0 | 1 | 14 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Depuy Synthes Spine, Inc. | 1 | 2014-11-18 |
| OrthoPediatrics Corp. | 1 | 2024-01-20 |

## Recent FDA 510(k) Clearances
- **`K233105`** (2024-01-20) — **OrthoPediatrics Corp.**: RESPONSE™ Rib and Pelvic System ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K233105))
- **`K142587`** (2014-11-18) — **Depuy Synthes Spine, Inc.**: Vertical Expandable Prosthetic Titanium Rib ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K142587))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "MDI"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*