# FDA Product Code NIM: Stent, Carotid

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/NIM
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=NIM
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/NIM/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=NIM

## FDA CDRH Classification Metadata
- **Product Code**: `NIM`
- **Device Name**: Stent, Carotid
- **Device Class**: Class 3
- **21 CFR Regulation Number**: `N/A`
- **Medical Specialty / Review Panel**: CV (CV)
- **Implantable**: True | **Life-Sustaining**: True | **Third-Party Eligible**: False
- **Definition**: Stent, Carotid -- a metal scaffold placed via a delivery catheter into the carotid artery to maintain the lumen

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 12 / 313
- **FDA AccessGUDID Published Devices**: 222
- **FDA MAUDE Adverse Event Reports**: 8,831 (Deaths: 704, Injuries: 5,686, Malfunctions: 2,392)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 6 | 181 | 8 |
| 2020 | 0 | 0 | 0 | 163 | 1 |
| 2021 | 0 | 0 | 0 | 201 | 8 |
| 2022 | 0 | 0 | 0 | 172 | 4 |
| 2023 | 0 | 0 | 7 | 172 | 3 |
| 2024 | 0 | 2 | 14 | 265 | 3 |
| 2025 | 0 | 1 | 31 | 593 | 21 |
| 2026 | 0 | 0 | 6 | 566 | 26 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| No 510(k) applicants recorded | 0 | — |

## Recent FDA 510(k) Clearances
- No recent 510(k) clearances recorded for this product code.

## Recent FDA PMA Approvals & Supplements
- **`P240009`**/S010 (2026-11-20) — **Contego Medical, Inc.**: Neuroguard IEP® 3-in-1 Carotid Stent, Post-Dilation Balloon System with Integrated Embolic Protection ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240009S010))
- **`P240029`**/S005 (2026-11-09) — **InspireMD, Ltd.**: CGuard Prime TransCarotid Stent System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240029S005))
- **`P060001`**/S060 (2026-11-05) — **Medtronic Vascular, Inc.**: PROTEGE GPS AND PROTEGE RX CAROTID STENT SYSTEMS ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P060001S060))
- **`P240009`**/S006 (2026-11-04) — **Contego Medical, Inc.**: Neuroguard IEP® 3-in-1 Carotid Stent, Post-Dilation Balloon System with Integrated Embolic Protection ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240009S006))
- **`P060001`**/S059 (2026-10-16) — **Medtronic Vascular, Inc.**: Protégé™ GPS™ Self-Expanding Peripheral Stent System; Protégé™ RX Self-Expanding Carotid Stent System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P060001S059))
- **`P240009`**/S012 (2026-07-29) — **Contego Medical, Inc.**: Neuroguard IEP® 3-in-1 Carotid Stent and Post-Dilatation Balloon System with Integrated Embolic Protection ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240009S012))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "NIM"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*