# FDA Product Code NPU: Prosthesis, Mitral Valve, Percutaneously Delivered

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/NPU
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=NPU
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/NPU/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=NPU

## FDA CDRH Classification Metadata
- **Product Code**: `NPU`
- **Device Name**: Prosthesis, Mitral Valve, Percutaneously Delivered
- **Device Class**: Class 3
- **21 CFR Regulation Number**: `N/A`
- **Medical Specialty / Review Panel**: CV (CV)
- **Implantable**: True | **Life-Sustaining**: True | **Third-Party Eligible**: False
- **Definition**: These devices are intended to replace a patient's mitral heart valve.  They are different from the classified device (heart valves) in that they are placed percutaniously and do not require open chest surgery or a cardiotomy for placement.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 2 / 10
- **FDA AccessGUDID Published Devices**: 73
- **FDA MAUDE Adverse Event Reports**: 2,081 (Deaths: 432, Injuries: 1,500, Malfunctions: 149)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 15 | 30 | 2 |
| 2020 | 0 | 0 | 0 | 218 | 72 |
| 2021 | 0 | 0 | 0 | 248 | 57 |
| 2022 | 0 | 0 | 5 | 213 | 59 |
| 2023 | 0 | 0 | 0 | 288 | 60 |
| 2024 | 0 | 0 | 0 | 280 | 51 |
| 2025 | 0 | 2 | 32 | 315 | 72 |
| 2026 | 0 | 0 | 5 | 427 | 53 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| No 510(k) applicants recorded | 0 | — |

## Recent FDA 510(k) Clearances
- No recent 510(k) clearances recorded for this product code.

## Recent FDA PMA Approvals & Supplements
- **`P240042`**/S004 (2026-08-31) — **ABBOTT MEDICAL**: Tendyne Transcatheter Mitral Valve System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240042S004))
- **`P240042`**/S003 (2026-08-07) — **ABBOTT MEDICAL**: Tendyne™ Transcatheter Mitral Valve System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240042S003))
- **`P250019`**/S006 (2026-07-29) — **Edwards Lifesciences, LLC**: Edwards SAPIEN M3 Dock (988DDS); Edwards 23F Guide Sheath (9880GS); Edwards SAPIEN M3 Crimper (9880CR); Edwards Commande ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250019S006))
- **`P250019`**/S005 (2026-07-28) — **Edwards Lifesciences, LLC**: SAPIEN M3 Transcatheter Heart Valve (9880TFX29M) ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250019S005))
- **`P250019`**/S003 (2026-04-16) — **Edwards Lifesciences, LLC**: SAPIEN M3 Transcatheter Mitral Valve Replacement System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250019S003))
- **`P250019`**/S002 (2026-03-11) — **Edwards Lifesciences, LLC**: Edwards SAPIEN M3 Transcatheter Heart Valve (sizes 20mm, 23mm, 26mm, 29mm) ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250019S002))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "NPU"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*