# FDA Product Code OOB: Drug-Eluting Percutaneous Transluminal Coronary Angioplasty Catheter

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/OOB
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=OOB
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/OOB/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=OOB

## FDA CDRH Classification Metadata
- **Product Code**: `OOB`
- **Device Name**: Drug-Eluting Percutaneous Transluminal Coronary Angioplasty Catheter
- **Device Class**: Class 3
- **21 CFR Regulation Number**: `N/A`
- **Medical Specialty / Review Panel**: CV (CV)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: A drug-eluting percutaneous transluminal coronary angioplasty catheter is a combination product intended for balloon dilatation of a hemodynamically significant coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion.  A drug-eluting ptca catheter may also be intended for the treatment of acute myocardial infarction; Treatment of in-stent restenosis (isr) and/or post-deployment stent expansion.  A drug-eluting ptca catheter delivers a drug to the vessel as part of the angioplasty procedure, which is intended to inhibit restenosis.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 2 / 10
- **FDA AccessGUDID Published Devices**: 60
- **FDA MAUDE Adverse Event Reports**: 673 (Deaths: 76, Injuries: 208, Malfunctions: 388)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2024 | 0 | 1 | 28 | 141 | 12 |
| 2025 | 0 | 0 | 0 | 230 | 46 |
| 2026 | 0 | 1 | 32 | 302 | 18 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| No 510(k) applicants recorded | 0 | — |

## Recent FDA 510(k) Clearances
- No recent 510(k) clearances recorded for this product code.

## Recent FDA PMA Approvals & Supplements
- **`P230035`**/S008 (2026-11-13) — **Boston Scientific Corporation**: AGENT™ Paclitaxel-Coated Balloon Catheter Matrix Expansion (40 mm Balloon Length) ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P230035S008))
- **`P250041`**/S001 (2026-11-06) — **MedAlliance, LLC**: SELUTION SLR™ 014 PTCA Drug-Eluting Balloon ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250041S001))
- **`P250041`** (2026-09-18) — **MedAlliance, LLC**: SELUTION SLR™ 014 PTCA Drug-Eluting Balloon ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P250041))
- **`P230035`**/S010 (2026-08-28) — **Boston Scientific Corporation**: AGENT Paclitaxel-Coated Balloon Catheter ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P230035S010))
- **`P230035`**/S009 (2026-07-30) — **Boston Scientific Corporation**: AGENT™ Paclitaxel-Coated Balloon Catheter ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P230035S009))
- **`P230035`**/S006 (2026-02-11) — **Boston Scientific Corporation**: AGENT Paclitaxel-Coated Balloon Catheter ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P230035S006))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "OOB"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*