# FDA Product Code QCR: Wound Autofluorescence Imaging Device

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/QCR
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=QCR
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/QCR/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=QCR

## FDA CDRH Classification Metadata
- **Product Code**: `QCR`
- **Device Name**: Wound Autofluorescence Imaging Device
- **Device Class**: Class 1
- **21 CFR Regulation Number**: `878.4165`
- **Medical Specialty / Review Panel**: SU (SU)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: A wound autofluorescence imaging device is a tool to view autofluorescence images from skin wounds that are exposed to an excitation light. The device is not intended to provide quantitative or diagnostic information.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 1
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 2
- **FDA MAUDE Adverse Event Reports**: 0 (Deaths: 0, Injuries: 0, Malfunctions: 0)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2018 | 0 | 0 | 0 | 0 | 0 |
| 2025 | 0 | 0 | 1 | 0 | 0 |
| 2026 | 0 | 0 | 1 | 0 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| MolecuLight, Inc. | 1 | 2018-07-31 |

## Recent FDA 510(k) Clearances
- **`DEN180008`** (2018-07-31) — **MolecuLight, Inc.**: MolecuLight i:X ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=DEN180008))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "QCR"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*