# FDA Product Code QHJ: Sensor, Glucose, Implanted, Non-Adjunctive Use

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/QHJ
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=QHJ
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/QHJ/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=QHJ

## FDA CDRH Classification Metadata
- **Product Code**: `QHJ`
- **Device Name**: Sensor, Glucose, Implanted, Non-Adjunctive Use
- **Device Class**: Class 3
- **21 CFR Regulation Number**: `N/A`
- **Medical Specialty / Review Panel**: CH (CH)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: A non-adjunctive implanted glucose sensor is intended to determine glucose   levels, and the direction and rate of change of glucose levels in people with   diabetes. The device is indicated to replace information obtained from standard   blood glucose monitoring devices to make diabetes-related treatment decisions. The device also provides historical glucose information, facilitating long-term therapy adjustments.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 0
- **FDA De Novo Grants**: 0
- **FDA PMA Originals / Supplements**: 0 / 16
- **FDA AccessGUDID Published Devices**: 33
- **FDA MAUDE Adverse Event Reports**: 2,545 (Deaths: 0, Injuries: 1,250, Malfunctions: 1,293)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 7 | 0 | 0 |
| 2020 | 0 | 0 | 0 | 18 | 0 |
| 2021 | 0 | 0 | 0 | 9 | 0 |
| 2022 | 0 | 0 | 15 | 173 | 0 |
| 2023 | 0 | 0 | 2 | 341 | 0 |
| 2024 | 0 | 0 | 1 | 915 | 0 |
| 2025 | 0 | 0 | 0 | 635 | 0 |
| 2026 | 0 | 0 | 0 | 454 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| No 510(k) applicants recorded | 0 | — |

## Recent FDA 510(k) Clearances
- No recent 510(k) clearances recorded for this product code.

## Recent FDA PMA Approvals & Supplements
- **`P160048`**/S029 (2025-03-27) — **Senseonics, Incorporated**: EVERSENSE CONTINUOUS GLUCOSE MONITORING SYSTEM ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S029))
- **`P160048`**/S025 (2023-06-09) — **Senseonics, Incorporated**: Eversense E3 Continuous Glucose Monitoring System (CGM System) - Entire System, Eversense E3 Sensor, Eversense E3 Insert ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S025))
- **`P160048`**/S024 (2023-05-10) — **Senseonics, Incorporated**: Eversense E3 CGM System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S024))
- **`P160048`**/S022 (2023-03-30) — **Senseonics, Incorporated**: Eversense® E3 Continuous Glucose Monitoring (CGM) System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S022))
- **`P160048`**/S021 (2023-03-29) — **Senseonics, Incorporated**: Eversense® E3 Continuous Glucose Monitoring (CGM) System ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S021))
- **`P160048`**/S023 (2023-03-22) — **Senseonics, Incorporated**: Eversense E3 Continuous Glucose Monitoring System (CGM System) - Entire System, Eversense E3 Sensor, Eversense E3 Insert ([FDA PMA](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P160048S023))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "QHJ"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*