# FDA Product Code QJI: Interoperable Automated Glycemic Controller

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/QJI
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=QJI
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/QJI/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=QJI

## FDA CDRH Classification Metadata
- **Product Code**: `QJI`
- **Device Name**: Interoperable Automated Glycemic Controller
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `862.1356`
- **Medical Specialty / Review Panel**: CH (CH)
- **Implantable**: False | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: An interoperable automated glycemic controller is a device intended to automatically calculate drug doses based on inputs such as glucose and other relevant physiological parameters, and to command the delivery of such drug doses from a connected infusion pump. Interoperable automated glycemic controllers are designed to reliably and securely communicate with digitally connected devices to allow drug delivery commands to be sent, received, executed, and confirmed. Interoperable automated glycemic controllers are intended to be used in conjunction with digitally connected devices for the purpose of maintaining glycemic control.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 24
- **FDA De Novo Grants**: 1
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 48
- **FDA MAUDE Adverse Event Reports**: 5,524 (Deaths: 4, Injuries: 1,836, Malfunctions: 3,680)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2019 | 0 | 0 | 3 | 0 | 0 |
| 2020 | 1 | 0 | 0 | 1 | 0 |
| 2021 | 0 | 0 | 4 | 1 | 0 |
| 2022 | 2 | 0 | 2 | 4 | 0 |
| 2023 | 4 | 0 | 6 | 26 | 0 |
| 2024 | 4 | 0 | 14 | 15 | 0 |
| 2025 | 5 | 0 | 17 | 3 | 1 |
| 2026 | 8 | 0 | 2 | 5,474 | 3 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Tandem Diabetes Care, Inc. | 6 | 2026-04-24 |
| Insulet Corporation | 6 | 2026-06-29 |
| Beta Bionics, Inc. | 3 | 2026-09-11 |
| Medtronic Minimed, Inc. | 2 | 2026-01-14 |
| Medtronic Minimed | 1 | 2026-02-03 |
| Tidepool Project | 1 | 2023-01-23 |
| CamDiab | 1 | 2026-09-16 |
| Diabeloop | 1 | 2025-12-19 |
| Deka Research and Development Corp. | 1 | 2026-10-15 |
| Deka Research and Development | 1 | 2024-03-13 |

## Recent FDA 510(k) Clearances
- **`K262576`** (2026-10-15) — **Deka Research and Development Corp.**: twiist Loop Algorithm ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K262576))
- **`K261896`** (2026-09-16) — **CamDiab**: iOS CamAPS FX ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K261896))
- **`K262763`** (2026-09-11) — **Beta Bionics, Inc.**: iLet Dosing Decision Software ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K262763))
- **`K261962`** (2026-07-09) — **Medtronic MiniMed**: SmartGuard Technology; Predictive Low Glucose Technology ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K261962))
- **`K261461`** (2026-06-29) — **Insulet Corporation**: Omnipod 6 algorithm ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K261461))
- **`K260429`** (2026-04-24) — **Tandem Diabetes Care, Inc.**: Control-IQ+ technology ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K260429))
- **`K253701`** (2026-02-03) — **Medtronic Minimed**: SmartGuard Technology; Predictive Low Glucose Technology ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K253701))
- **`K253585`** (2026-01-14) — **Medtronic Minimed, Inc.**: SmartGuard technology; Predictive Low Glucose technology ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K253585))
- **`K251152`** (2025-12-19) — **Diabeloop**: DBLG2 ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K251152))
- **`K251779`** (2025-12-03) — **Insulet Corporation**: Omnipod 5 algorithm ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K251779))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "QJI"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*