## FDA CDRH Classification Metadata
- **Product Code**: `QNI`
- **Device Name**: Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `888.3044`
- **Medical Specialty / Review Panel**: OR (OR)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: A resorbable implant for anterior cruciate ligament (ACL) repair is a degradable material that allows for healing of a torn ACL that is biomechanically stabilized by traditional suturing procedures. The device is intended to protect the biological healing process from the surrounding intraarticular environment and not intended to replace biomechanical fixation via suturing. This classification includes devices that bridge or surround the torn ends of a ruptured ACL.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 2
- **FDA De Novo Grants**: 1
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 1
- **FDA MAUDE Adverse Event Reports**: 43 (Deaths: 0, Injuries: 10, Malfunctions: 33)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2020 | 0 | 0 | 0 | 0 | 0 |
| 2021 | 0 | 0 | 1 | 0 | 0 |
| 2024 | 0 | 0 | 0 | 2 | 0 |
| 2025 | 1 | 0 | 0 | 29 | 0 |
| 2026 | 1 | 0 | 0 | 12 | 0 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Miach Orthopaedics, Inc. | 3 | 2026-01-13 |

## Recent FDA 510(k) Clearances
- **`K251214`** (2026-01-13) — **Miach Orthopaedics, Inc.**: BEAR® (Bridge-Enhanced ACL Restoration) Implant ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K251214))
- **`K243578`** (2025-03-06) — **Miach Orthopaedics, Inc.**: BEAR® (Bridge-Enhanced ACL Restoration) Implant ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K243578))
- **`DEN200035`** (2020-12-16) — **Miach Orthopaedics, Inc.**: BEAR (Bridge-Enhanced ACL Repair) Implant ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=DEN200035))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "QNI"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*