# FDA Product Code SBA: Integrated Continuous Glucose Monitoring System With Sensor Containing Dexamethasone Acetate

> US Federal Regulatory & Post-Market Safety Dossier · Meridian by Mountain Wave (updated regularly)

- **Canonical URL**: https://meridian.mountainwave.ai/code/SBA
- **Interactive Explorer**: https://meridian.mountainwave.ai/explorer?domain=fda&product_code=SBA
- **REST API v1**: `GET https://meridian.mountainwave.ai/api/v1/product-codes/SBA/dossier`
- **Official FDA Classification**: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpcd/classification.cfm?ID=SBA

## FDA CDRH Classification Metadata
- **Product Code**: `SBA`
- **Device Name**: Integrated Continuous Glucose Monitoring System With Sensor Containing Dexamethasone Acetate
- **Device Class**: Class 2
- **21 CFR Regulation Number**: `862.1357`
- **Medical Specialty / Review Panel**: CH (CH)
- **Implantable**: True | **Life-Sustaining**: False | **Third-Party Eligible**: False
- **Definition**: An integrated continuous glucose monitoring system (iCGM) with sensor containing dexamethasone acetate is intended to automatically measure glucose in bodily fluids continuously or frequently for a specified period of time. iCGM systems are designed to reliably and securely transmit glucose measurement data to digitally connected devices, including automated insulin dosing systems, and are intended to be used alone or in conjunction with these digitally connected medical devices for the purpose of managing a disease or condition related to glycemic control.  The dexamethasone acetate coating is intended to reduce inflammation at the sensor insertion site.

## Cumulative Multi-Domain Federal Totals
- **FDA 510(k) Clearances**: 2
- **FDA De Novo Grants**: 1
- **FDA PMA Originals / Supplements**: 0 / 0
- **FDA AccessGUDID Published Devices**: 14
- **FDA MAUDE Adverse Event Reports**: 4,136 (Deaths: 1, Injuries: 903, Malfunctions: 3,215)

## Annual Regulatory & Post-Market Totals

| Year | 510(k) Clearances | PMA Originals | GUDID Published | MAUDE Events | MAUDE Deaths |
| :---: | :---: | :---: | :---: | :---: | :---: |
| 2024 | 1 | 0 | 10 | 17 | 0 |
| 2025 | 0 | 0 | 0 | 1,173 | 0 |
| 2026 | 1 | 0 | 4 | 2,946 | 1 |

## Top 510(k) Clearance Holders

| Manufacturer / Applicant | 510(k) Clearances | Latest Clearance |
| :--- | :---: | :---: |
| Senseonics, Incorporated | 3 | 2026-11-20 |

## Recent FDA 510(k) Clearances
- **`K263888`** (2026-11-20) — **Senseonics, Incorporated**: Eversense 365 Continuous Glucose Monitoring (CGM) System ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K263888))
- **`K241335`** (2024-09-16) — **Senseonics, Incorporated**: Eversense 365 Continuous Glucose Monitoring (CGM) System ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K241335))
- **`DEN230052`** (2024-04-29) — **Senseonics, Incorporated**: Eversense AP CGM System ([FDA CDRH](https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=DEN230052))

## Query via Native MCP Server (`POST https://meridian.mountainwave.ai/mcp`)

```json
{
  "jsonrpc": "2.0",
  "id": 1,
  "method": "tools/call",
  "params": {
    "name": "get_product_code_dossier",
    "arguments": {"product_code": "SBA"}
  }
}
```

---
*Statutory Notice: Data sourced from US FDA public releases (CDRH / openFDA / AccessGUDID / MAUDE). Do not rely on openFDA or Meridian data to make decisions regarding medical care. While FDA makes every effort to ensure data accuracy, users should verify regulatory status directly against official FDA CDRH databases.*